Hover Ceiling OGE Unfactored Headwind - OEI 2.5 min
Rotor speed: PLUS · Electrical load: 100% · OAT lines: -40..+50°C · Headwind treated as headwind component only
Max GW (kg)
4250
Chart reference: AW169 RFM Supplement 5 (External Hoist, Goodrich) · Figure S5-31 Hover Ceiling OGE Unfactored Headwind - OEI 2.5 min · Page S5-55 · Issue 3 Rev. 1
Assumptions: OAT Multi (-40..+50 C), Rotor speed PLUS, Electrical load 100%. Headwind treated as headwind component.
Headwind planning credit: Headwind is automatically reduced by 50% in accordance with the QRH. Enter the actual wind.
Disclaimer: For training/planning aid only. Verify against the RFM before flight.